Manual
Enviado por Miriam Sanchez • 25 de Agosto de 2015 • Informe • 460 Palabras (2 Páginas) • 119 Visitas
[pic 1][pic 2][pic 3][pic 4][pic 5][pic 6]
[pic 7]
1 | ||
2 | ||
ON 3 | 1 - CPU ON LED | |
_ |
| |
12345678 6 _ | 4 – Not used 5 – Unit testing 6 - Protection cover Fixing holes | |
6 | 4 | |
5 | ||
Selector Functions Dip 1 OFF= Update mode ON= Operating mode | ||
Dip 2,3 DIP 3 DIP 2 RS-485 baud rate ON ON 115200 baud ON OFF 38400 baud OFF ON 19200 baud OFF OFF 9600 baud Dip 4,5,6 Vision System ID ( B trough I ) | ||
Dip 7 OFF= Mean Value Detection ON= Peak Value Detection |
[pic 8][pic 9][pic 10]
[pic 11]
Main characteristics
[pic 12]
Power supply voltage | 24V ( 15VDC - 30VDC) | ||
Current consumption ( 24V ) | 180mA | ||
Sensor type | CCD 2048 pixels | ||
Spectral response | 400 nm – 700nm | ||
Output type | PNP ( NPN as option ) | ||
Signals | Red LED - Power ON Signal | ||
Yellow LED - Detect object Signal | |||
Green LED - Blinking CPU Working | |||
Basic sensitivity adjustment | By means of internal lens diaphragm | ||
Baud Rate Programming | By means of Dip 2, 3 of Selector unit, accessible from the case bottom. See SELECTOR FUNCTIONS on first page. | ||
Vision System ID | By means of Dip 4, 5, 6 of Selector unit, accessible from the case bottom. See SELECTOR FUNCTIONS on first page. | ||
Type of lenses being used | 50 mm NIKON lenses (other types of lenses for different framings are available on request) | ||
Available focal lenses upon request | 28 mm - 100 mm - 200 mm | ||
Focusing | By means of focus ring on the lens | ||
Minimum focusing distance | 400mm (200mm with additional lenses) | ||
Framed field (50 mm lenses) | 240mm a 500 mm distance from the object | ||
Protections | Reverse polarity protection | ||
Anti splashes frontal protection on request | |||
Extended temperature range housing on request | |||
Anti condensing function on request | |||
Connection | 12-pin TRIDENT male panel connector | ||
Unit cooling | Housing provided with hermetically sealed water-air cooling or heating circuit with ¼” GAS threads on the rear side | ||
Working temperature range | 0°C ÷ + 40°C with water or air cooling the range can be extended | ||
Storing temperature range | - 20°C ÷ + 70°C |
...