NPSH required (NPSHr) and tips
What factors should be taken into account in NPSH required? What are the top tips for conducting a diffusion pump system efficient?
Topic: Tips for the installation of metering pumps
Source: Hidrofluidos
Hidrofluidos
Add to My archivist Business
Increase size
Zoom out
Usually supports add online charging losses to internal NPSH required of the pump. You can deduct losses in static NPSH available online.
- Internal NPSH required: internal NPSH required of a metering pump is generally not taken into account in case of inviscid fluids.
- Effects of inertia (DH): inertia losses are dominant. You can consider NPSH r = DH
The following formula gives the maximum value of the depression generated by the pump at the start of the suction phase:
DH expressed in meter liquid column (mcl) with:
L: length of the suction pipe (m)
Q: maximum rated flow. Pump (l / h)
N: nominal dose rate (gpm)
d: inner diameter of the suction pipe (mm).
Check NPSH
Installation is good, low NPSH standpoint, if the NPSHd exceeds the NPSHr. Given the particular nature of the dosing pumps generally retained security equal to 2 mcl be checked that:
Installation Tips-Importance of Accessories
Suction
A short suction pipe, large diameter, limiting the elbows and avoiding the "swan neck" favors the suction conditions.
- Foot valve - artichoke. Indispensable from the time that the pump is installed "on aspiration." Minimizes the risk of restriking and is provided with a filter element.
- Filter. Imperative when the pump is installed "in charge". Prevents accumulation of solid particles in the valve boxes, thereby guaranteeing precision and durability.
Pressure pipe
The discharge pipe should be as direct as possible. Its sizing and accessories will be determined according to the terms of service.
- Cane injection. Mounted on the injection site, acts as a check valve. Crea, moreover, a backpressure that prevents eventual artificial siphoning.
- Check valve (calibrated valve or back pressure). Artificial creates a back to be regulated in order to avoid any over-flow.
- Safety valve. Located in the drive circuit, protects the metering pump to the pipe and fittings, in the event of accidental overpressure (eg valve closing).
- Damper. Gas Backup Device compressible flow pulsations damps pressure and usually generated by the pump. Is necessary in the discharge pipes of great length, and for pumping high cadences. Requires minimal backpressure of about 1 bar (relative) and should be placed as close to the pump.